Field case · Precision oxygenation · ODIN O₂

The site's highest-biomass cage, among the most stable in oxygen

At a salmon farm in Chile's Los Lagos Region with a history of critical oxygen drops, CPI installed ODIN O₂ in a single cage: the one with the highest biomass and heaviest fish on site, and therefore the highest oxygen demand. With all 14 cages measured by the client's same sensor, that cage ranked #1 in load and #2 in oxygen stability.

Client
Salmon farm
(confidential)
Location
Los Lagos Region · Chile
Technology
ODIN O₂ oxygenation — CPI Equipment
Setup
1 cage with ODIN O₂ · 14 cages measured
Period
From start-up · May 2026
~197 t
of biomass in the ODIN O₂ cage: the highest on site (#1 of 14), with fish 7.5% heavier than average
83.0%
of the time within the optimal DO range (5.5–6.5 mg/L), vs. a 77.6% average for the current system
71.9%
of the time within ±0.3 mg/L of target, vs. 51–67% in neighboring cages
p<0.001
in all 4 paired comparisons with neighboring cages (n > 17,000 readings each)
The challenge

01 Holding oxygen in range where demand is highest

The operational question is not how much peak oxygen you reach, but how long the water stays in the right range.

A site at the lower edge of the range. The site operates in early winter, near the lower limit of the optimal range, with a history of critical oxygen drops.

The demanding moments. Feeding, tides, and demand peaks are what test oxygen control in each cage.

The hardest cage, on purpose. CPI installed ODIN O₂ in the highest-biomass cage. If the system works in the most demanding cage, the result is hard to argue with.

The metric that matters. We measure how long each cage stays within the optimal 5.5–6.5 mg/L range and how precisely it holds around target. That is the biologically correct metric for fish welfare.

Reference optimal range: 5.5–6.5 mg/L. Below 5 mg/L is considered hypoxia.

Methodology

02 A clean comparison: the client's sensor, the same conditions

A cage-to-cage comparison is only valid if every cage is measured the same way. Here, they are.

Reference sensor: the same oxygen sensor model at 5 m, installed by the site itself in all 14 cages. CPI did not touch the measurement.

Data volume: 91,084 synchronized readings, one every 5 minutes per cage, from diffuser start-up.

Uniform conditions: temperature (11.1–11.4 °C) and salinity (32 PSU) practically identical across cages.

Cross-check. Readings were checked on site against the production manager's YSI probe.

The site's own data. The figures come from the client's instrument, not a CPI sensor. CPI Equipment performed the analysis.

ODIN O₂ vs. the current system

03 Cage by cage, with the same sensor

The ODIN O₂ cage (J103) vs. the four neighboring cages on the site's current system. Switch between the two views.

Reading. The ODIN O₂ cage beats all four neighbors on both metrics: 83.0% of the time in range (+5.4 pp over the current system's average) and 71.9% of the time within ±0.3 mg/L of target. All 4 paired comparisons are statistically significant (p<0.001).

The usual objection, ruled out. Among the site's 14 cages, the ODIN cage is #1 in biomass and #2 in oxygen stability (CV 6.6%). No cage on the current system combines both: the advantage isn't explained by a lighter biological load.

When oxygen gets tight

04 Less hypoxia and more oxygen contribution

How much each cage raises oxygen above the site's ambient oxygen, and how long it spends below 5 mg/L.

Reading. The ODIN O₂ cage recorded the largest contribution of the five cages compared (+0.84 mg/L above the site's ambient oxygen, vs. +0.65 to +0.81 mg/L) and only 0.1% of the time below 5 mg/L: a single 0.7-hour episode across the whole window. The margin shows up in the cage that needs it most.

Value for the operation

05 What this means for the site

01
The hardest test
ODIN O₂ ran in the site's highest-biomass cage with the heaviest fish, the one with the highest oxygen demand, and was still among the most stable.
02
More time in the right range
83.0% of the time in the optimal range, vs. 77.6% for the current system: +5.4 percentage points.
03
More precise control
71.9% of the time within ±0.3 mg/L of target, vs. 51–67% in neighboring cages.
04
Less hypoxia
0.1% of the time below 5 mg/L and the largest contribution above ambient oxygen among the cages compared.
05
Attributable to the system
With uniform temperature and salinity across cages, the difference doesn't come from the environment: it comes from how oxygen is controlled.
06
Measured, not claimed
91,084 readings from the site's own sensor and 4 paired comparisons with p<0.001.

The study focused on dissolved oxygen. Lower stress, better feed intake, or lower risk of critical events are expected consequences based on fish physiology, not results measured in this case.

When the cage with 197 tonnes of biomass outperforms less demanding cages in stability, the conversation stops being about equipment and becomes about operational control.
ODIN O₂: #1 in biomass and #2 of 14 in oxygen stability
Field case prepared by CPI Equipment Chile (June 2026). Data source: the farm site's own oxygen monitoring · reference sensor at 5 m, same model in all 14 cages · window from diffuser start-up (May 2026) · 91,084 readings. The optimal DO range is defined as 5.5–6.5 mg/L. Site and client identity withheld for confidentiality.